FRN18.5LM1S-4C

FRN18.5LM1S-4C

Model No.︰FRN18.5LM1S-4C

Brand Name︰FRN18.5LM1S-4C

Country of Origin︰Japan

Unit Price︰CNY ¥ 13000 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

FRENIC-LIFT Fuji Inverter for Elevator FRN45LM1S-4C
Compared with the previous products, it has many advantages, such as greatly reducing the torque ripple and so on. It is bound to cooperate with the customer's system in order to play a more outstanding function and characteristics.
Characteristic
Special design suitable for passenger elevator use.
It has a high performance over-load capacity of 200%-10s, and its current response speed is five times faster than that of the original UD series.
The standard IM/PMSM frequency converter can drive asynchronous tractor and control synchronous tractor.
Corresponding to a variety of PG pulse signal reception. Standard + 12V/+15V A/B/Z, optional card 5V line drive. The card also corresponds to Heidehan Heiden Hain Endat 2.1, 4-bit GRAY codes and three U, V, W encoders.
primary coverage
Power Supply and Model
Rated input AC voltage
Input Voltage Level Capacity Input AC Voltage
Three-phase 400V 5.5kW~30kW 380V~480V 50/60Hz
Permissible fluctuation of input power supply
Voltage: +10%-15%
Frequency: +5%-5%
Voltage imbalance rate: less than 2% (IEC61800-3 (5.2.3) as standard)

Capacity range
Three-phase 400V:5.5~30kW
Output frequency range
Lift(L1):01-120 Hz
Specification outline
Items and Specifications
Series Name FRN_L1MS-
Rated overload current 200%-10s rated output current
Rated Frequency 50,60 Hz
Braking time 30S
Brake usage (% ED) 50
Acceleration and deceleration time varying from 0.01 to 99.99s
Frequency setting signal DC0 ~ + - 10V (DC0 ~ + - 5V) terminal 12, V2
DC4~20mA Terminal C1 Road
Functions: Forced stop, S-curve range, simultaneous setting of multi-step speed instructions, reversal of digital input and output logic, soft start at startup, feed-forward compensation of speed regulator, vibration suppression observer, digital analog torque offset, password function, crawl-free operation, battery operation, self-learning of magnetic pole position
Protection Functions: Overcurrent, Short Circuit Protection, Grounding Protection, Overvoltage Protection, Input Phase-absence Protection, Output Phase-absence Protection, Electronic Thermal Relay, PTC Thermistor, Overload Protection, Overspeed Protection, EN Circuit Abnormality, PG Encoder Break, Instantaneous Outage Protection
Compliance with safety specifications EN50178:1997
Protection structure
(IEC 60529) IP20 closed 5.5-22kW
Cooling mode: fan cooling (5.5~22kW 3 phase 400V)
1 FRN5.5LM1S-4C 10KVA 13.5A 5.5KW 3 phase AC380V/50Hz/60Hz 7700
2 FRN7.5LM1S-4C 14 KVA 18.5A 7.5KW 3 phase AC380V/50Hz/60Hz 8000
3 FRN11LM1S-4C 18 KVA 24.5A 11KW 3 phase AC380V/50Hz/60Hz 10500
4 FRN15LM1S-4C 24 KVA 32.0 A 15 KW 3 phase AC380V/50Hz/60Hz 12080
5 FRN18.5 LM1S-4C 29 KVA 39.0 A 18.5 KW 3 phase AC380V/50Hz/60Hz 16730
6 FRN22LM1S-4C 34 KVA 45.0 A 22KW 3 phase AC380V/50Hz/60Hz 19570
7 FRN30LM1S-4C 30KW 3 phase AC380V/50Hz/60Hz 25975
8 FRN37LM1S-4C 37KW 3 phase AC380V/50Hz/60Hz 40643
9 FRN45LM1S-4C 45KW 3 phase AC380V/50Hz/60Hz 48850
PP Card 1180 for 10 OPC-LM1-PP Synchronous Motor
11 OPC-LM1-PR card 1740 for synchronous motor
12 OPC-LM1-PS synchronous motor PS card 1620
13 TP-G1-CLS Operating Panel 1050

Payment Terms︰ kuandaofahuo